Title 24 Reports Inglewood

Title 24 Reports and Energy Calculations for Inglewood

Title 24 Calcs prepares permit-ready Title 24 energy reports for Inglewood. We cover new homes, ADUs, garage conversions, room additions, remodels, and commercial projects throughout the city. Most residential reports ship within 1-2 business days. Inglewood is part of our full California cities service area.

Inglewood has changed faster than almost any city in Los Angeles County over the past decade. The stadium and Hollywood Park district brought large-scale commercial and mixed-use construction, while the city's older residential stock continues to generate steady ADU and garage conversion permits. Every one of these projects needs a Title 24 CF1R energy compliance report before permits can be issued.

Which code year applies to your Inglewood permit

The 2025 California Energy Code took effect January 1, 2026. Every permit pulled on or after that date must comply. Projects permitted before then still fall under the 2022 code. We work from the permit approval stamp, not the date the plans were drawn, because that is the date the building department uses.

Inglewood Title 24 key facts:
• Provider: Title 24 Calcs prepares CF1R energy compliance reports for Inglewood
• Climate zone: Zone 8, warmer inland conditions with higher cooling loads than coastal Zone 6
• Building department: City of Inglewood Building and Safety Division, 1 Manchester Blvd, Inglewood, CA 90301
• Phone: (310) 412-5294  |  Counter hours: Mon to Thu 8:00 to 5:00, Fri 8:00 to 12:00
• Local amendments: None on the CEC list of ordinances exceeding the 2025 Energy Code. State code applies as written.
• Starting price: $250 for eligible residential projects
• Turnaround: 1-2 business days for most residential reports

Jump to your project type:

CF1R Reports and HERS Testing in Inglewood

Inglewood Building and Safety requires a CF1R Certificate of Compliance for residential permits that trigger Title 24. Title 24 Calcs prepares the CF1R in CEC-approved software updated to the 2025 code, and registers it with an approved HERS provider before delivery, so your set is ready for plan check submittal.

CF1RCertificate of Compliance, prepared at design and submitted with your Inglewood plan check set CF2RCertificate of Installation, signed by the installing contractor in the field CF3RCertificate of Verification, signed by a HERS Rater before Inglewood final inspection

HERS Testing Requirements in Inglewood

HERS testing is third-party field verification, not something that can be signed off on paper. A certified HERS Rater must verify these measures before final occupancy:

  • Duct leakage testing on new or substantially altered duct systems
  • Heat pump and air conditioner refrigerant charge verification
  • Whole-house mechanical ventilation flow rate
  • Airflow and fan watt draw on ducted systems
  • Quality Insulation Installation, where the compliance run takes credit for it

Ductless mini-splits avoid most of these, which is one reason they appear so often on Inglewood garage conversions and smaller ADUs. Your CF1R identifies every HERS measure that applies, and we flag them in writing when we confirm scope so nothing surfaces late.

Inglewood Title 24 Climate Zone 8

Inglewood sits in California Title 24 Climate Zone 8. This one catches people out. Inglewood is roughly four miles from the coast, and neighboring Westchester is Zone 6. The climate zone boundary runs between them. Hawthorne and Lawndale, immediately to the south, are also Zone 8.

The practical consequence is that an Inglewood home needs more insulation, better-performing windows, and a larger solar system than a comparable home in El Segundo or Playa del Rey, because the compliance formula applies a higher cooling load factor to Zone 8. Design to Zone 6 values on an Inglewood project and the calculations will not comply. We confirm the zone by project address, never by city name, and addresses near a boundary get checked individually.

Zone 8 compliance details for Inglewood:
Ceiling insulation minimum R-38  |  Wall insulation R-15 or R-13+4ci  |  Window U-factor 0.30 or less  |  Window SHGC 0.23 or less  |  Solar PV sized to the Zone 8 capacity factor  |  Heat pump baseline for space and water heating. The California Energy Commission climate zone tool confirms your parcel's zone assignment.

Nearby cities we also serve: Hawthorne  •  Gardena  •  Torrance  •  Culver City  •  Compton. See the full Los Angeles service page or our California cities index for every city we cover.

Title 24 Services We Provide for Inglewood Permits

New Home Construction in Inglewood

New single-family homes in Inglewood need a Title 24 new construction report for every permit submitted on or after January 1, 2026. Under the 2025 code, heat pumps are the prescriptive baseline for both space and water heating. Solar PV sized to the Zone 8 formula and battery readiness wiring apply to most new homes. We run the PV calculation against the Solar Access Roof Area rather than estimating from square footage, because the 1.8 kWdc exemption threshold is where a lot of money gets spent unnecessarily. See our residential new construction service page for full details.

Title 24 ADU, JADU, Granny Flat, and In-Law Unit Reports in Inglewood

Inglewood's older housing stock has made it one of the more active ADU markets in the South Bay, and garage conversion is the most common scope we see here. A Title 24 ADU report is required for every detached ADU, attached ADU, JADU, granny flat, and in-law unit. The compliance path differs between new construction classification and alteration classification, and we confirm which applies before starting. See our Title 24 ADU service page for more information.

The garage conversion trap: converting unconditioned space to conditioned living space counts as new construction under Title 24, not as an alteration. The full Section 150.1 requirements apply, including water heating and the solar PV provisions. It is the most common misunderstanding we see on Los Angeles County ADU projects, and it is far cheaper to catch at design than after a plan check correction.

Room Additions in Inglewood

A room addition in Inglewood that adds conditioned floor area triggers Title 24 compliance. New walls, ceilings, and windows must meet Zone 8 insulation and fenestration values, and any new HVAC or ductwork must meet 2025 efficiency and leakage standards. The question that usually decides the compliance path is whether the existing system can serve the new area or needs upgrading. See our room addition service page and alteration service page for details.

Remodels and Alterations in Inglewood

Not every Inglewood remodel needs a Title 24 report, but many do. These scopes commonly trigger an energy compliance report at the permit counter:

  • HVAC replacement, where a new furnace, heat pump, or AC system may need load calculations and duct testing
  • Window replacement, where Zone 8 U-factor and SHGC minimums apply to all new windows
  • Water heater replacement, where a gas to heat pump switch triggers ventilation and electrical panel requirements
  • Re-roof with insulation work, where the envelope rules apply to the altered assembly

Commercial Title 24 in Inglewood

Inglewood has had sustained commercial and mixed-use activity around the stadium and Hollywood Park district, along the Century and La Cienega corridors, and through the older retail stock along Market Street. We prepare NRCC-ENV, NRCC-MCH, and NRCC-LTI forms for tenant improvements, shell buildings, retail, restaurant, medical office, and hospitality projects. The 2025 code expanded design review and commissioning requirements on nonresidential work, so early involvement saves redesign later.

Inglewood Local Title 24 Amendments: What You Need to Know

Some California cities adopt local energy ordinances that go beyond the state code. These are called reach codes, and the California Energy Commission has to approve them before they take effect. Inglewood has not adopted one.

  • No local energy reach code: Inglewood does not appear on the CEC list of approved ordinances exceeding the 2025 Energy Code
  • No county-level ordinance either: no Los Angeles County jurisdiction currently appears on that list
  • State code applies as written: your Zone 8 compliance targets are the 2025 statewide values, with nothing layered on top
  • CALGreen is separate: CALGreen applies independently of Title 24 Part 6, and your plan check set needs documentation for both

Reach codes do get adopted and amended between code cycles, so this is worth confirming at the counter on any project. We check the current status before preparing a report rather than assuming last year's answer still holds.

Frequently Asked Questions: Title 24 Inglewood

Does Inglewood require a Title 24 report for building permits?

Yes. The City of Inglewood Building and Safety Division requires a CF1R Title 24 energy compliance report for new construction, ADUs, room additions, and many alterations. It is submitted as part of the plan check package at 1 Manchester Blvd, Inglewood, CA 90301. Phone: (310) 412-5294.

What Title 24 climate zone is Inglewood in?

Climate Zone 8. Neighboring Westchester is Zone 6, so the zone cannot be assumed from proximity to the coast. Zone 8 carries higher cooling loads, which means your Inglewood project needs more ceiling insulation, stricter window performance, and a larger solar system than a comparable project a few miles west.

What is HERS testing and is it required in Inglewood?

HERS testing is third-party field verification of energy systems. A certified HERS Rater must verify duct leakage, refrigerant charge, ventilation flow rates, and other measures before final occupancy. Your CF1R identifies which HERS measures apply to your project.

Do I need a Title 24 report for a garage conversion in Inglewood?

Yes, and the requirements are stricter than most people expect. Converting a garage to conditioned living space counts as new construction under Title 24, not as an alteration. The full Section 150.1 requirements apply, including water heating and solar PV. We confirm the compliance path before starting.

Does Inglewood have local energy code amendments?

No. Inglewood does not appear on the CEC list of local ordinances exceeding the 2025 Energy Code, and neither does any other Los Angeles County jurisdiction. State energy code applies as written. CALGreen still applies separately from Title 24 Part 6.

How much does a Title 24 report cost in Inglewood?

Pricing starts at $250 for eligible residential projects in Inglewood. All pricing includes HERS registration, plan-sized PDFs, and revision support. See our pricing page for current rates.

How long does it take to get a Title 24 energy report in Inglewood?

Most residential reports are delivered within 1-2 business days after we receive complete plans. Commercial reports typically take 2-3 business days. Rush options are available for time-sensitive submittals.

Order Title 24 Calcs / Energy Calculation Report for projects in Inglewood

Order Form

    Residential Projects

    Floor plan including North Arrow

    Dimensioned exterior elevation

    Window & door schedules

    Heating and cooling equipment type

    Hot water system type and capacity

    Non HERS Verified : CF1R-ADD, CF1R ALT, CF1R-ENV,CF1R-PLB,CF1R-LTG and CF1R STH HERS CF1R,CF2R and CF3R
    forms

    Non-Residential/Commercial Projects

    Floor plan including North Arrow (NRCC-ENV)

    Dimensioned exterior elevation

    Sections , wall , roof and window detail

    Window & door schedules (unless indicated on plan)

    Mechanical plan (NRCC-MCH,NRCC-PLB Forms only)

    Lighting plan (NRCC-LTI Forms Only)

    NRCC-CXR,NRCC-ELC,NRCC-ENV,NRCC-LTI,NRCC-MECH,NRCC-PLB,NRCC-ELC

    Upload File Here

    Please wait while your files transfer it may take several minutes. (Uploading files like .jpeg, .zip,
    .dwg, .pdf, .txt)